Shure AXT600 Axient Spectrum Manager
Shure AXT600 Axient Spectrum Manager
The Axient Spectrum Manager is a powerful tool for calculating, analyzing and assigning compatible frequencies to wireless components. The Spectrum Manager scans the RF environment and uses this data to calculate compatible frequencies for all wireless channels found on the network. Networked wireless systems can be programmed from the Compatible Frequency List, while backup frequencies are continuously monitored and ranked according to quality. During operation, the Spectrum Manager deploys clear frequencies to receivers when interference occurs. Built-in spectrum monitoring tools provide visual and audio tracking of RF activity.
Features:
- Scans and analyzes the global UHF spectrum (470-952 MHz) in approximately one minute
- Continuously monitors, evaluates, and displays backup frequencies in real time
- Enables powerful RF protection features such as series automatic interference detection and avoidance via ShowLinkâ„¢
- Compatible with Axient Digital and other Shure networked wireless systems, and works seamlessly with Wireless Workbench Software
- Easily connects to your computer or ShowLink Access Point via two Ethernet ports
- IEC in/out power ports enable daisy-chaining of AC power
Specifications:
- RF Tuning Frequency Range: 470–865, 925–952 MHz
- RF Tuning Step Size: 25, 200, 1000 kHz
- Noise Floor:
- Resolution Bandwidth:
- 25 kHz: -110 dBm
- 200 kHz: -100 dBm
- 1000 kHz: -90 dBm
- Resolution Bandwidth:
- Image Rejection: >110 dB, typical
- Spurious Response: <-100 dBm, typical
- Ultimate Quieting: >90 dB, A-Weighted
- Dimensions: 44 mm x 483 mm x 366 mm (1.7 in. x 19.0 in. x 14.4 in.) H x W x D
- Weight: 5.5 kg (12.0 lbs.)
- Housing: Steel; Extruded aluminum
- Power Requirements: 100 to 240 V AC, 50–60 Hz
- Current Drain: referenced at 120 V AC, 0.8 A RMS
- Operating Temperature Range: -18°C (0°F) to 63°C (145°F)
- Storage Temperature Range: -29°C (-20°F) to 74°C (165°F)
- Scan Time: The Spectrum Manager scans the entire RF tuning frequency range in 64 seconds using 8 scanning modules in parallel. Scan time per 60 MHz may be less for specified ranges that allow scanning modules to work in parallel.
- Step Size Maximum Scan Time per 60 MHz:
- 25 kHz: 48 seconds
- 200 kHz: 7 seconds
- 1000 kHz: 1 second
- RF Input:
- Connector Type: BNC
- Configuration: Unbalanced, Active
- Impedance: 50 Ω
- Maximum Input Level: -20 dBm
- Bias Voltage: 12 V DC, 150 mA (300 mA maximum)
- Cascade Output:
- Connector Type: BNC
- Configuration: Unbalanced, Active
- Impedance: 50 Ω
- Insertion Loss: <5 dB
- Monitor Audio Output
- Audio Frequency Response: 40–18 kHz, ±3 dB
- Configuration: Unbalanced mono, 1/4 in. Output (will drive stereo phones)
- Impedance: 50 Ω
- Maximum Signal Level:
- 45 kHz max. deviation
- 1 W @ 63 Ω
- Pin Assignments:
- Tip: audio +
- Ring: audio +
- Sleeve: ground
- Networking:
- Power over Ethernet (PoE): 50 V DC, Class 1
- Network Interface: Dual Port Ethernet 10/100 Mbps
- Network Addressing Capability: DHCP or Manual IP address